AP240 — Energy Recovery Facility, Utility & Auxiliary Systems
Package: Plant & Instrument Air Package (Area Code 4119) — Material Requisition, Part I: Equipment/Material Supply
Document No.: AP240-0000-00-MR-4119-01
Revision: A Status: Issued for Inquiry (IFI)
Bids shall be submitted in English, in SI units, in accordance with the format and structure requested in the Vendor Document Requirement List (VDR), Doc. No. AP240-0000-00-VR-4119-01.
VENDOR shall confirm receipt of this RFQ within 3 working days of issue and shall notify CONTRACTOR without delay of any intent not to bid.
4.2 Deemed Compliance and Cost Recovery
VENDOR's bid is deemed fully compliant with all RFQ documents (this MR, the PTS, the datasheets, the ITP, and all referenced attachments) unless a deviation is explicitly declared by VENDOR on the List of Deviations form, Doc. No. AP240-0000-00-QE-4119-01, and submitted with the bid. Silence on any clause, requirement, or datasheet value is taken by CONTRACTOR as full compliance.
No additional price, schedule relief, or other commercial recovery will be allowed after Purchase Order award for any correction, rework, or modification required to bring VENDOR's supply into compliance with the RFQ documents, irrespective of whether the non-compliance was identified by CONTRACTOR, CLIENT, a third-party inspector, or VENDOR itself, unless such non-compliance was the subject of a deviation accepted in writing by CONTRACTOR prior to Purchase Order.
Prototype or unproven equipment, defined as equipment with less than five (5) years of continuous, successful operating record in comparable service, is not acceptable and will not be evaluated unless VENDOR has obtained CONTRACTOR's specific written qualification agreement in advance of bid submission.
4.3 Order of Precedence of Documents
In the event of conflict or discrepancy between RFQ documents, the following order of precedence shall apply (highest first), unless a specific clause states otherwise:
1. Purchase Order and its terms and conditions (post-award)
2. This Material Requisition (Part I)
3. Particular Technical Specification, AP240-0000-00-PTS-4119-01
4. Equipment Datasheets, AP240-0000-00-DS-4119-01
5. Attached general specifications and appendices (Section 5)
6. Applicable codes, standards, and statutory regulations referenced therein
7. VENDOR's standard specifications and catalogues (informative only, lowest precedence)
Any conflict identified by VENDOR between documents of equal or adjacent precedence shall be raised as a bid clarification query; it shall not be resolved unilaterally by VENDOR.
4.4 Spare Parts Pricing
See what Loonar reads in your documents.
Book 30 minutes and bring a real RFQ. We run your own package through Loonar and show you only what deviates: every non-standard clause, every contradiction, each one traceable to its page.